™
XPress Ethernet Bridge
Product Manual - Commercial/Indoor XEB09-C
Create long range wireless links in minutes!
Connect any Ethernet device to the XPress Ethernet Bridge
RF Modems and the bridge will function in place of
an Ethernet cable. The Ethernet bridge provides a
transparent wireless point-to-point cable replacement.
© 2006 MaxStream, Inc. All rights reserved.
M100257
Introduction
This manual provides step-by-step instruction on how to setup a wireless link and test the
Ethernet Bridge’s ability to transport data over varying ranges and conditions.
Included with the XPress Ethernet Bridge (Commercial)
(2) XPress Ethernet Bridge RF Modems
(2) 6 VDC/80-240 VAC power adapters (not included w/ version XEB09-C-AU (Australia))
(2) Half-wave, 2.5 dBi, dipole antennas w/RPTNC connector
Quick Setup
Hardware Setup
1. Plug both RF Modems into power outlets using the included power adaptors.
(If operating in Australia: Use power adapters that meet Australian regulations and the
supply voltage specifications cited on page 4 this manual.)
2. Connect an Ethernet cable from each XPress RF Modem to a network device.
3. Send Ethernet traffic through the wireless Ethernet Bridge [for troubleshooting, refer to
the following page].
Each RF Modem automatically selects the best radio channel, encrypts the Ethernet traffic and
transports the data wirelessly to its matched pair. Cross-over cables are not necessary since the
RF modems automatically sense the device (client vs. switch).
Figure 1. Ethernet Bridge Setup
Advanced Settings
Automatic Frequency Selection Mode (All DIP Switches OFF (up))
<Default Configuration> The RF modem is designed to automatically select and continuously
optimize the performance of its radio channel. The radio channel is monitored to ensure it is
providing low error rates necessary for successful radio transmission. In the event that the
error rate rises, the RF modem will autonomously change to a new channel. There are 12 non-
overlapping channels.
Figure 2. DIP Switches ‐ Automatic Frequency Selection Mode (All OFF (up))
Australia only: In order to comply with Australian regulations, all modems intended for use in
Australia are pre-configured to operate on 6 channels and DIP Switches are disabled.
Manual Frequency Selection Mode
To restrict the operation of the RF modem to a subset of the 902-928 band, the user may acti-
vate a manual selection mode that allows the radio to automatically choose the best channel
within a grouped subset of the 12 available channels. This is enabled by the 8-position DIP
switch on the master unit. These settings allow the RF modem to operate on the optimal chan-
nel in one of three subsets: LOW 4, MID 4 or HIGH 4.
Channels
LOW 4 - 1,2,3 or 4
MID 4 - 5,6,7 or 8
HIGH 4 - 9,10,11 or 12
Frequency Range
903-909 MHz
DIP Settings
2 ON / 3 OFF
2 OFF / 3 ON
2 ON / 3 ON
911-917 MHz
919-925 MHz
Or - the user may wish to select a specific channel. This can be done by setting DIP switches 5-
8 as shown in the table below. [Turn DIP 2 Off / 3 Off]
Channel
Frequency
903 MHz
905 MHz
907 MHz
909 MHz
911 MHz
913 MHz
915 MHz
917 MHz
919 MHz
921 MHz
923 MHz
925 MHz
DIP Settings
1
2
3
4
5
6
7
8
9
5 On / 6 Off / 7 Off / 8 Off
5 Off / 6 On / 7 Off / 8 Off
5 On / 6 On / 7 Off / 8 Off
5 Off / 6 Off / 7 On / 8 Off
5 On / 6 Off / 7 On / 8 Off
5 Off / 6 On / 7 On / 8 Off
5 On / 6 On / 7 On / 8 Off
5 Off / 6 Off / 7 Off / 8 On
5 On / 6 Off / 7 Off / 8 On
5 Off / 6 On / 7 Off / 8 On
5 On / 6 On / 7 Off / 8 On
5 Off / 6 Off / 7 On / 8 On
10
11
12
Site Survey Mode (DIP Switch 4 is ON (down))
In this mode the RF modem can perform a site survey. With this mode activated the radios send
and receive at 100% capacity by transceiving self-generated simulated data. The installer can
monitor the Link Quality display to assess channel quality while optimizing antennae orienta-
tion. The installer can manually select each channel to evaluate performance and identify the
best channels for operation. By identifying channels with poor performance it is possible to
identify possible interferers and use "Manual Frequency Selection Mode" to avoid portions of
the band or select a fixed operating frequency.
Important Note: Ethernet traffic does not get transported while the RF modems are in Site Survey Mode.
Technical Specifications
Specification
Description
Power Output
125 mW (21 dBm) conducted, 4 Watts EIRP w/ 15 dBi antenna
RF Data Rate
1.5 Mbps
935 Kbps
Throughput Data Rate
Receiver Sensitivity
Latency
-4
-97 dBm @10e BER (-112 dBm w/ 15 dBi antennas)
< 1ms - assuming a dedicated wireless link to client device
±0.5 ms - depending upon packet size, interference and SNR
12 Non-overlapping
Jitter
Radio channels
Automatic frequency select
Manual frequency mode
Status LEDs
Yes - radio channel automatically selected and adaptively optimized
Yes
Power, RF Link, Ethernet Link, Traffic, RF RX, RF TX, 4/Channel and 6/Link Quality
Sub-block error-detection and retransmission
SAW receiver filter attenuates cellular and pager interference
350 mA
Error-correction technique
Adjacent band rejection
Transmit current consumption
PoE (Power over Ethernet)
Proprietary 9V system - includes injectors and power supplies
Supply Voltage (Temperature Range) 4.5 - 9.0 VDC (for -40 °- 70° C)
up to 16.0 VDC (for -40° - 35° C)
United States (FCC part 15.247)
Industry Canada (IC)
R4N-AW900M
5303A-AW900M
FCC Compliance
Compliance Statement (Part 15.19)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
Warning (Part 15.21)
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to
operate the equipment.
RF Exposure (OET Bulletin 65)
To comply with FCC RF exposure requirements for mobile transmitting devices, this transmitter should only be used or installed
at locations where there is at least 20 cm separation distance between the antenna and all persons.
Information to the User - Part 15.105 (b)
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
--Reorient or relocate the receiving antenna.
--Increase the separation between the equipment and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
--Consult the dealer or an experienced radio/TV technician for help.
This product should be installed ONLY by experienced, professional installers who are familiar with local building and safety
codes, and wherever applicable, are licensed by the appropriate authorities. Failure to do so may void the warranty and may
expose the user or the service provider to legal and financial liabilities.
Contact MaxStream
Phone:
(801) 765-9885
OnLine Chat:
e-mail:
|