n
Master Station with Selective Door Release
TC-10MD 10-Call Master
TC-20MD 20-Call Master
- SUPPLEMENT TO TC-M INSTRUCTIONS -
The TC-MD Intercom and Selective Door Control System is designed for communication between a central master
station and remote door stations. The TC-MD adds door release to the standard TC-M system. All information
regarding installation other than the external control functions is included in the TC-M instructions. In addition to
communication to remote locations, the Master Station can selectively release the corresponding door strike or
maglock.
WIRING DIAGRAM: SYSTEM USED FOR SELECTIVE DOOR RELEASE
TC-10MD
TB-AD1
For Door #10
IE/IF Door
Station
TB-AD1
For Door #9
1
2
3
~
9
1
2
IE/IF Door
Station
1
2
1
2
1
2
10
E
TC-20MD
N
T
R
+
-
N
T
R
+
-
T
R
12+
12-
M
Door Release button
Located below
C
TRANSFER button.
Relays are activated
when the door
release button is
being pressed while
a station button is
selected.
Momentary Closure for Station #1
RY-PA
#1
1
~
9
BLK
YEL
Momentary Closure for Station #9
Momentary Closure for Station #10
RY-PA
#9
BLK
YEL
BLK
10
L
RY-PA
#10
YEL
Common for each closure
PS-1820UL
To convert RY-PA to N/C (normally
closed) contact: Move one yellow wire
from "NO" to "NC". (Internal
modification, soldering required.)
+
-
AC/
DC
Input
x
x
AC Power
for Door
Releases
Individual Components for System:
TC-MD TERMINAL DEFINITIONS:
TC-nMD
RY-PA
Master station with selective contact output capability (10, 20)
Relay for selective output (1 per station requiring external contact)
18V DC, 2A Power Supply
1 Audio Door Adaptor
10 Audio Door Adaptor
+
-
1~10
E
M,C
T
Power input (18V DC or 16V AC)
Negative
Station number
Common communication
Master-to-Master communication
Transmit to door station
Receive from door station
Output to call extension speaker
PS-1820UL
TB-AD1
TB-AD10
TB-ADM10
IMPORTANT:
1. RY-PA must be used for each selective contact to
isolate AC voltage from the intercom circuit.
2. Extra contact connections and L are on the
external terminal block.
10 Video Door Adaptor
R
S, S
SEPARATE TERMINAL BLOCK LOCATED INSIDE MASTER:
1~10 (20) Selective negative for each channel
L
Common Positive output for selective closure
Pg. 1
|
Boss Audio Systems Car Amplifier A4 User Manual
Burnham Independence IN3 User Manual
Cres Cor Star Series Carving Stations IFW61RR User Manual
Eizo FlexScan Color LCD Monitor S2232W User Manual
Farenheit Technologies HRD 9GR User Manual
FujiFilm 16229347 User Manual
Hobie 30116 User Manual
HP (Hewlett Packard) CB350 User Manual
JVC Car Video System KD AVX44J User Manual
JVC GR D200 User Manual